he purpose of this study is to evaluate the stress on trabecular bone and cortical bone located in trabecular bone with single prostheses supported by implants using the Finite Element Analysis (FEA) method. This experimental method was carried out by producing 3.5mm diameter implant models, followed by trabecular bone and mandibular bone models using Catia V5R21. After the model is produced FEA will be carried out using Abaqus CAE. Criteria for data collection is using von Misses values. In conclusion, cortical bone did not show significant differences, and trabecular bone showed higher tensile stress with reduction in implant diameter.